FD580 Ultrasonic Flaw Detector
 Features:
- Automated calibration of transducer Zero Offset and/or Velocity
- Automated gainã€Peak Hold and Peak Memory
- Automated display precise flaw location(Depth d,level p,distance s,amplitude,sz dB,Ñ„)
- Automated switch three staff gauge ((Depth d,level p,distance)
- Ten independence setup, any criterion can be input freely, we can work in the scene without test block
- Big memory of 300 A graph and 30000 thickness value
- B scan
- RS232 communication interface
- The embedded software can be online updated
- Li battery, continue working time up to 8 hours
- Other assistant function
- Display freeze
- Automated echo degree
- Angles and K-value
- Lock and unlock function of system parameters
- Dormancy and screen savers
- Electronic clock calendar
- Two gates setting and alarm indication
- High-speed capture and very low noise
- DAC,AVG,B Scan; Solid metal housing (IP65)
- Automated make video of test process and play
- Provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness and easy to read from all angles
- Powerful pc software and reports can be export to excel
Technical Specification Scanning range (mm) | Scanning range (mm):2.5~10000Steps: 2.5, 5, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 2000, 3000, 4000, 5000, 6000, 7000, 8000, 9000 and 10000.Step:0.1mm (2.5 mm~99.9mm),1mm (100mm~10000mm) | Display delay (μs) | D-delay (μs):-20~+3400 Stage: -20, -10, 0.0, 10, 20, 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3400.Step: 0.1 (-20μs~999.9μs), 1 (1000μs~3400μs) | Probe delay (μs) | P-delay: 0.0~99.99Step: 0.01 | Sound velocity in material (m/s) | Sound velocity in material: 1000~99997 fixed sound velocities: 2260, 2730, 3080, 3230, 4700, 5900, 6300Step: 1 | Working method | Single probe (P/R), double probes (transceiver), transmission (transmission probe) | Frequency ranges (MHz) | Low frequency 0.2-1, middle frequency 0.5-4, high frequency 2-20, three steps optional | Gain (dB) | 0~110Step: 0.0, 0.2, 0.5, 1, 2, 6, 12 | Linear suppression | 0%~80% of screen height, step: 1% | Vertical linear error | Less than 3% | Level linear error | Less than 1% within scanning range | Detection sensitivity margin | ≥60dB | Dynamic scope | 60dB | Alarm | Traveling-wave alarm, evanescent wave alarm | Monitoring gate | 2 gates, represents with horizontal thick line with adjustable start point, width and height.Start point(mm): horizontal pixel 0~208, with display value relating to scanning range.Step: mm quantity corresponding to one pixel (relating to scanning range)Width(mm): horizontal pixel 4~212, with display value relating to scanning range.Step: mm quantity corresponding to one pixel (relating to scanning range)Height: vertical scale 2%~90%Step: 1% | Display | EL highlight dot matrix4 background color available | A-Scan display | Full screen or partA-Scan display of freezing and de-freezing A-Scan filling | Wave display | All wave | Detecting channel | 10 | Data storage | 300 A-Scan images (30 for each channel)30000 thickness values (300 groups) | Communication port with PC | RS232 | Unit | mm/inch | Power adaptor | Input 100 Hz -240 Hz~50 Hz /60HzOutput 9V~12VDC/3A~4A | Battery | Li battery 4x3.6V 4000mAh | Ambient temperature (°C) | 0~40 | Ambient humidity (RH) | 20%~90% | Interface | BNC | Outline (mm) | 240x173x50 | Weight (kg) | 2.2 |
|